Stop Time Measurement (ISO 13855)
Inertia tests with calibrated instrumentation for precise validation of safety distances.
The Problem We Solve
Empirical installation of optical barriers (light curtains) and physical protections, allowing the operator to reach the hazard zone before the machine stops completely. This poses an imminent risk of amputations and severe legal liabilities in audits.
High-Precision Instrumentation
Tests based on ISO 13855 using calibrated instrumentation. We perform multiple field measurements with statistical treatment to determine the exact braking time. The safe distance is validated in a structured manner based on inertia and reach parameters.
Test Parameters (Instrumentation Rule)
Traceable Deliverables