Medição de tempo de parada em prensa industrial
ISO 12100 · ISO 13849 · NR-12 · NR-10

Stop Time Measurement (ISO 13855)

Inertia tests with calibrated instrumentation for precise validation of safety distances.

Diagnosis

The Problem We Solve

Empirical installation of optical barriers (light curtains) and physical protections, allowing the operator to reach the hazard zone before the machine stops completely. This poses an imminent risk of amputations and severe legal liabilities in audits.

Methodology

High-Precision Instrumentation

Tests based on ISO 13855 using calibrated instrumentation. We perform multiple field measurements with statistical treatment to determine the exact braking time. The safe distance is validated in a structured manner based on inertia and reach parameters.

Equipamento HHB DT3 Safetyman
HHB Instrumentation (Traceable Calibration)
Instrumentation

Test Parameters (Instrumentation Rule)

Base Equipment Safetyman DT2 / DT3 (HHB Electronic)
Reading Accuracy Milissegundos (Tratamento estatístico)
Atuador Simulador de interrupção ótica/mecânica
Deliverables

Traceable Deliverables

  • Technical report on geometric conformity
  • Machine braking curves and graphs
  • Technical calculation of safe distance
  • Technical Responsibility Note
  • Medição em campo
    Validation of geometric distance

    Solicite um Ensaio de Tempo de Parada